Façade Project Evolution

This page compares information contained in the Phase I Structural Assessment Report and the subsequent Façade Restoration Project Manual prepared by Falcon Engineering.

The purpose of this page is to help owners understand how the project evolved between the initial engineering assessment and the subsequent construction specifications.

The observations below are based solely on the engineering documents currently available to owners.

ComponentPhase I Structural Assessment ReportFaçade Project ManualOwner Questions
Porte Cochere SkylightsCouple cracked panels, partial replacement as needed.Removal and replacement of all skylight panels and associated roofing components.What engineering analysis or findings led to the expansion from localized repairs to complete replacement?
Exterior PaintingAreas of deterioration and maintenance needs identified.Complete exterior painting program.Was complete repainting required for certification?
SealantsDeficiencies identified in certain locations.Extensive sealant replacement.What criteria were used to determine the extent of replacement?
Balcony RepairsBalcony-related deficiencies identified.Extensive balcony restoration and waterproofing work.What engineering analysis or findings led to doing anything beyond the original report?
Waterproofing & CoatingsVarious maintenance items identified.Broad waterproofing and coating program.What portions of this work actually required for certification?

Note: This table is intended to compare information contained in the engineering documents currently available to owners. It does not attempt to determine whether any particular project component is necessary or unnecessary. Owners are encouraged to review the source documents and draw their own conclusions.